Worked examples
The built-in example in meters
You enter
- Total rise
- 2.8
- Risers
- 16
- Tread depth
- 0.28
- Unit
- Meters
You get
- Rise per step
- 0.18 m
- Treads
- 15
- Total run
- 4.2 m
- Pitch angle
- 32.01°
- Stringer length
- 5.05 m
2.8 divided by 16 is exactly 0.175, which the page rounds to 0.18. Fifteen treads of 0.28 make a run of 4.2, and the stringer is the diagonal of a 2.8 by 4.2 triangle.
Run through the tool’s own code.
The same stairs in centimeters
You enter
- Total rise
- 280
- Risers
- 16
- Tread depth
- 28
- Unit
- Centimeters
You get
- Rise per step
- 17.5 cm
- Treads
- 15
- Total run
- 420 cm
- Pitch angle
- 32.01°
- Stringer length
- 504.78 cm
Switching to centimeters shows the exact step height, 17.5, which the meter view had to round. The angle is the same because only the unit changed.
Run through the tool’s own code.
Imperial units: a nine foot rise
You enter
- Total rise
- 108
- Risers
- 14
- Tread depth
- 10
- Unit
- Inches
You get
- Rise per step
- 7.71 in
- Treads
- 13
- Total run
- 130 in
- Pitch angle
- 37.65°
- Stringer length
- 169.01 in
Nine feet is 108 inches. Divided by 14 risers it gives 7.71 inches each. There are 13 treads of 10 inches, so the run is 130 inches.
Run through the tool’s own code.
A metric flight in centimeters
You enter
- Total rise
- 270
- Risers
- 15
- Tread depth
- 25
- Unit
- Centimeters
You get
- Rise per step
- 18 cm
- Treads
- 14
- Total run
- 350 cm
- Pitch angle
- 35.75°
- Stringer length
- 442.04 cm
270 divided by 15 is a clean 18. With 14 treads of 25 the run is 350, and the angle is steeper than in the first example because the steps are taller and shallower.
Run through the tool’s own code.
A rise that is too small
You enter
- Total rise
- 0.2
- Risers
- 16
- Tread depth
- 0.28
- Unit
- Meters
You get
- Error
- Enter a number above zero for each required measurement. Check the optional values too.
The total rise must be at least 0.3 meters, so 0.2 is refused. The message is general and does not name the limit, so check the ranges in this guide.
Run through the tool’s own code.
A fractional riser count
You enter
- Total rise
- 2.8
- Risers
- 16.5
- Tread depth
- 0.28
- Unit
- Meters
You get
- Error
- Enter a number above zero for each required measurement. Check the optional values too.
You cannot build half a step, so the riser count must be a whole number. The same error appears for counts below 2 or above 100.
Run through the tool’s own code.