Worked examples
Ideal case with no losses
You enter
- Mode
- energy
- Capacity
- 100 Wh
- Load
- 10 W
- Depth of discharge percent
- 100
- Efficiency percent
- 100
You get
- Nominal energy
- 100 Wh
- Usable energy
- 100 Wh
- Runtime
- 10 h
- Days
- 0.42 d
With nothing lost, 100 watt-hours feeds a 10 watt load for 100 divided by 10, which is 10 hours.
Run through the tool’s own code.
With assumed 80 percent usable and 90 percent efficient
You enter
- Mode
- energy
- Capacity
- 100 Wh
- Load
- 10 W
- Depth of discharge percent
- 80
- Efficiency percent
- 90
You get
- Nominal energy
- 100 Wh
- Usable energy
- 72 Wh
- Runtime
- 7.2 h
- Days
- 0.3 d
100 times 0.8 times 0.9 is 72 usable watt-hours. Divided by 10 W, that is 7.2 hours.
Run through the tool’s own code.
Amp-hours and volts
You enter
- Mode
- ah
- Capacity ah
- 100
- Voltage
- 12.8
- Load
- 200 W
- Depth of discharge percent
- 80
- Efficiency percent
- 85
You get
- Nominal energy
- 1,280 Wh
- Usable energy
- 870.4 Wh
- Runtime
- 4.35 h
- Days
- 0.18 d
100 Ah times 12.8 V is 1,280 Wh. Taking 80 percent and then 85 percent leaves 870.4 Wh, and 870.4 divided by 200 W is 4.352 hours.
Run through the tool’s own code.
A battery given in kilowatt-hours
You enter
- Mode
- energy
- Capacity
- 2 kWh
- Load
- 500 W
- Depth of discharge percent
- 90
- Efficiency percent
- 90
You get
- Nominal energy
- 2,000 Wh
- Usable energy
- 1,620 Wh
- Runtime
- 3.24 h
- Days
- 0.14 d
2 kWh is 2,000 Wh. After 90 percent and 90 percent, 1,620 Wh remain, and that lasts 3.24 hours at 500 W.