Vanlige spørsmål
How do I calculate three-phase power?
For a balanced load, apparent power is the square root of 3 times line voltage times line current. Multiply that by the power factor to get active power in watts. The tool does both steps and also shows reactive power from the same line values.
What is the difference between active, apparent and reactive power?
Active power, in watts, is the part that does work. Apparent power, in volt-amperes, is voltage times current without regard to timing. Reactive power, in var, swings back and forth with stored energy. Power factor is the ratio of active to apparent power.
Should I enter line voltage or phase voltage?
Enter the line-to-line voltage, the one measured between two line wires. On a 230/400 V supply that is 400 V. The tool then shows the phase voltage for star or delta. A phase voltage typed into the line box would give the wrong power.
Does star or delta change the total power?
No. For the same line voltage, line current and power factor the totals are identical. Only the phase values change. In star, phase voltage is line voltage divided by the square root of 3. In delta, phase current is line current divided by the square root of 3.
What happens when the power factor is 1 or 0?
At 1, active power equals apparent power and reactive power is 0. At 0, active power is 0 and all the apparent power is reactive. The tool accepts both values. Real loads rarely sit exactly at either end, so read the nameplate or a meter.
Can I use it for unbalanced loads?
No. It assumes the same load on all three phases and clean sine waves. Unbalanced loads, motors starting up and variable speed drives need measured data and a professional. Treat the result only as a rough guide for an ideal case.
Can I use it to size cables or breakers?
No. Cable size, protection and safety limits depend on local rules, installation method, temperature and more. This tool only multiplies the values you type. Ask a qualified electrician or engineer, and follow the electrical rules that apply where you live.
Which units are used, and can I enter kilovolts?
You can enter volts or kilovolts and amperes or kiloamperes. Results are always shown in watts, volt-amperes, var, volts and amperes. So 11 kV and 0.1 kA appear as large plain numbers, such as 1,809,993.09 W. Divide by 1,000 for kilowatts.
Are my numbers sent anywhere?
No. The page says the sums run in your browser and the values are not uploaded or saved. Close the tab and they are gone. Copy results places text on your clipboard only if you press that button.
Hvordan beregner jeg trefaseeffekt?
For et balansert trefasesystem er tilsynelatende effekt S = √3 × linjespenning × linjestrøm, aktiv effekt P = S × effektfaktor, og størrelsen på reaktiv effekt Q = S × √(1 − PF²). Tilsynelatende effekt for én fase er V × I. Anslagene forutsetter sinusformet vekselstrøm og balansert belastning i trefasemodus.
Lastes de elektriske verdiene mine opp?
Nei. Beregningen kjøres i denne nettleseren; verdiene du oppgir, lastes ikke opp eller lagres av dette verktøyet.
Hva er formelen for balansert trefaseeffekt?
Med linje-til-linje-spenning og linjestrøm er tilsynelatende effekt S = √3 × Vline × Iline. Aktiv effekt er P = S × PF. Dette forutsetter et balansert, sinusformet vekselstrømsystem.
Hva er forskjellen mellom stjerne- og trekantkobling?
I en balansert stjernekobling er fasespenningen lik linjespenningen delt på √3, og fasestrømmen er lik linjestrømmen. I en trekantkobling er fasespenningen lik linjespenningen, og fasestrømmen er linjestrømmen delt på √3. Den samlede effekten er den samme for de samme linjeverdiene.
Påvirker effektfaktoren den aktive effekten?
Ja. Aktiv effekt er tilsynelatende effekt multiplisert med effektfaktoren. Lavere effektfaktor gir mindre aktiv effekt ved samme linjespenning og linjestrøm. Størrelsen på den reaktive effekten anslås med S × √(1 − PF²).
Kan jeg bruke dette for ubalanserte belastninger eller prosjektering av elektrisk sikkerhet?
Nei. Dette er et idealisert anslag for enfase eller balansert trefase. Det analyserer ikke faseubalanse, harmoniske komponenter, kabling, utstyrsklassifisering, vern, fare for elektrisk støt eller brann eller lokale forskrifter.