Eksempler
A ten-turn air-core coil, 20 mm by 20 mm
Du skriver inn
- Modell
- Air-core single-layer solenoid
- Vindinger
- 10
- Spole diameter
- 20 mm
- Viklingslengde
- 20 mm
- Mål
- 1.36 µH
Du får
- Estimert induktans
- 1.357589 µH
- Vindinger for målet
- 11
- Geometri
- inside the stated Wheeler range
Wheeler's formula, with sizes in inches, gives about 0.013576 µH for each turn squared. Ten turns squared is 100, so the coil is about 1.36 µH. Ten turns land just under the target, so the tool rounds up to 11.
Kjørt med verktøyets egen kode.
Doubling the turns of the same coil
Du skriver inn
- Modell
- Air-core single-layer solenoid
- Vindinger
- 20
- Spole diameter
- 20 mm
- Viklingslengde
- 20 mm
Du får
- Estimert induktans
- 5.430356 µH
Inductance grows with the square of the turns in this model. Twice the turns means four times the inductance, and 1.357589 µH times 4 is 5.430356 µH.
Kjørt med verktøyets egen kode.
A toroid with AL 100 nH and a 1 mH target
Du skriver inn
- Modell
- Toroid with manufacturer AL value
- Vindinger
- 10
- AL-verdi
- 100 nH/turn²
- Mål
- 1 mH
Du får
- Estimert induktans
- 10 µH
- Vindinger for målet
- 100
Ten turns squared is 100, and 100 times 100 nH is 10,000 nH, which is 10 µH. For 1 mH you need 100 turns, because 100 squared is 10,000 and 10,000 times 100 nH is 1 mH.
Kjørt med verktøyets egen kode.
A short, wide coil that leaves the safe shape range
Du skriver inn
- Modell
- Air-core single-layer solenoid
- Vindinger
- 5
- Spole diameter
- 2 cm
- Viklingslengde
- 0.5 cm
Du får
- Estimert induktans
- 703.03712 nH
- Geometri
- outside the stated Wheeler range; treat with extra caution
The diameter is four times the winding length, which is past the limit the tool uses. A number still appears, but it is a weaker guess than in the first example.
Kjørt med verktøyets egen kode.