555-timerkalkulator

Beregn tidsforløpet for en vanlig 555-timerkrets. Bytt mellom astabil oscillator og monostabil engangspuls, oppgi motstands- og kondensatorverdier, og se tidsresultatene.

Ideelle førsteordensestimater. Faktisk tidsstyring varierer med valgt 555-IC, komponenttoleranse, kondensatorlekkasje, temperatur, parasittvirkninger og utgangsbelastning. Texas Instruments anbefaler å bruke en typisk NE555 ved 100 kHz eller lavere for å redusere forvrengning. Se databladet for den aktuelle komponenten.

Astabil oscillator: tHIGH = 0.693 × (RA + RB) × C; tLOW = 0.693 × RB × C; T = tHIGH + tLOW; f = 1/T; arbeidssyklus for utgangsbølgeformen = tHIGH/T. Monostabil engangspuls: tPULSE ≈ 1.1 × R × C. Datablad for Texas Instruments NE555

Hvordan fungerer 555-timerkalkulatoren?

Velg astabil modus for gjentatte høye og lave intervaller, eller monostabil modus for én puls. Oppgi tidskomponentene og velg enhetene deres. Likningene gir ideelle førsteordens estimater.

Veiledning

Slik bruker du 555-timerkalkulator

The 555 Timer Calculator estimates the timing of the usual 555 timer circuits. In astable mode, which repeats forever, you enter two resistors and a capacitor and get the high time, low time, period, frequency and duty cycle. In monostable mode, which makes one pulse, you enter a resistor and a capacitor and get the pulse width. The numbers are ideal estimates, not a circuit simulation.

Slik gjør du

  1. Choose the circuit mode: astable oscillator for a repeating signal, or monostable one-shot for a single pulse after a trigger.
  2. Enter the resistors. Astable mode uses RA and RB and monostable uses R. One unit menu covers all of them: ohms, kilohms or megohms.
  3. Enter the timing capacitor and pick its unit: farads, millifarads, microfarads, nanofarads or picofarads.
  4. Press Calculate timing, or Try an example to fill in sample values. Press Copy results to take the figures and the formulas with you.

Eksempler

Astable with RA = RB = 10 kilohms and C = 10 microfarads

Du skriver inn
Modus
astable
RA
10 kΩ
RB
10 kΩ
C
10 μF
Du får
Frekvens
4.810005 Hz
Periode
207.9 ms
Høytid på utgangen
138.6 ms
Lavtid på utgangen
69.3 ms
Arbeidssyklus for signalet
66.6667%
Andel utladningstid
33.3333%

High time is 0.693 times 20 kilohms times 10 microfarads, which is 0.1386 s. Low time is 0.693 times 10 kilohms times 10 microfarads, which is 0.0693 s. The period is their sum, 0.2079 s, and the frequency is 1 divided by that. These are the values the page fills in by default.

Kjørt med verktøyets egen kode.

A faster astable circuit

Du skriver inn
Modus
astable
RA
1 kΩ
RB
10 kΩ
C
10 nF
Du får
Frekvens
6.871435 kHz
Periode
145.53 μs
Høytid på utgangen
76.23 μs
Lavtid på utgangen
69.3 μs
Arbeidssyklus for signalet
52.381%
Andel utladningstid
47.619%

When RA is much smaller than RB, the high time is only a little longer than the low time, so the duty cycle gets close to 50%. It cannot go below 50% in this circuit.

Kjørt med verktøyets egen kode.

Monostable with R = 100 kilohms and C = 10 microfarads

Du skriver inn
Modus
monostable
R
100 kΩ
C
10 μF
Du får
Pulslengde
1.1 s

The pulse width is 1.1 times R times C, which is 1.1 times 100,000 ohms times 0.00001 farads, or 1.1 seconds. The pulse starts when the circuit is triggered and ends by itself.

Kjørt med verktøyets egen kode.

Når det er nyttig

  • Pick starting resistor and capacitor values for a blinking LED or a simple clock signal.
  • Estimate the length of a delay or a timed pulse from a one-shot circuit.
  • Check an existing schematic against the numbers you measured on the bench.
  • Work through homework or a lab handout on 555 timing.

Begrensninger

  • Results are ideal first-order estimates using 0.693 and 1.1 as constants. Real timing changes with the exact chip, part tolerance, capacitor leakage, temperature, wiring and output load.
  • Only the conventional circuits are covered: astable with RA, RB and C, and monostable with R and C. Variants such as a diode across RB are not modelled, and the output high time is never shorter than the low time.
  • Values must be above zero. Resistance is capped at 1 trillion ohms, capacitance at 1,000 farads and any result at 1 trillion seconds, otherwise the tool shows a check-your-inputs message.
  • It ignores supply voltage, trigger and reset wiring, and the limits of the part. It is not an approval for a design, so check the datasheet and measure the real circuit.

Tips

  • Every time is proportional to R times C, so a 5% resistor and a 10% capacitor can each shift the result by their full percentage.
  • For long delays, choose a capacitor with low leakage and measure the real delay, since leakage can shift the timing.
  • Start from a standard capacitor value, then compute the resistor you need, and enter the nearest standard resistor to see what you will actually get.

Kilder

Vanlige spørsmål

What is the difference between astable and monostable mode?

Astable mode makes the output switch high and low again and again, like an oscillator. Monostable mode makes one output pulse of a set length after a trigger and then waits for the next trigger.

Why is the duty cycle never below 50% in astable mode?

In the standard circuit the capacitor charges through RA and RB but discharges through RB only. So the high time, 0.693 times RA plus RB times C, is always at least the low time, 0.693 times RB times C.

What are the two duty cycle lines?

Output waveform duty cycle is the high time divided by the period. The discharge interval share is the low time divided by the period. They add up to 100%, and the Texas Instruments datasheet gives both definitions.

Which formulas does the tool use?

High time 0.693 x (RA + RB) x C, low time 0.693 x RB x C, period as their sum and frequency as 1 divided by the period. For one pulse it uses 1.1 x R x C. The Texas Instruments datasheet gives the same forms.

Why do I get a warning about 100 kHz?

Texas Instruments advises using a 555 at 100 kHz or below to reduce distortion. The tool warns when the result is above that. RA and RB of 1 kilohm with 100 picofarads gives about 4.81 MHz and triggers the note.

Why does my real circuit not match the numbers?

The formulas are ideal. Part tolerance, capacitor leakage, temperature, the chip you used, stray wiring and the load on the output all move the result. Measure the real circuit and adjust the part values.

Are my values uploaded or saved?

No. The page says the calculation runs in your browser and that the values are not uploaded or saved by the tool.

Hvordan fungerer 555-timerkalkulatoren?

Velg astabil modus for gjentatte høye og lave intervaller, eller monostabil modus for én puls. Oppgi tidskomponentene og velg enhetene deres. Likningene gir ideelle førsteordens estimater.

Lastes kretsverdiene mine opp?

Nei. Beregningen skjer i denne nettleseren. Verktøyet laster ikke opp eller lagrer verdiene.

Hva er forskjellen på astabil og monostabil modus?

Astabil modus gjentar høye og lave intervaller som en oscillator. Monostabil modus lager én utgangspuls etter et utløsersignal; denne kalkulatoren estimerer den ideelle pulslengden.

Hvorfor er arbeidssyklusen for den vanlige astabile bølgeformen minst 50 %?

I standardkretsen med RA/RB lades kondensatoren gjennom RA og RB, og utlades deretter bare gjennom RB. Derfor er det høye intervallet minst like langt som det lave. Andre topologier, for eksempel med en diode, kan endre dette.

Vil en ferdigbygd krets gi nøyaktig dette resultatet?

Nei. Beregningen bruker ideelle likninger og modellerer ikke en bestemt komponent eller komponenttoleranser. Kontroller databladet for den valgte timeren, og mål den ferdigbygde kretsen.